Voltage on switch due to a lack of earth

Voltage on switch due to a lack of earth in Tenby

Periodic Inspection and Testing

We carry out Electrical Inspection and Testing in Tenby, Saundersfoot, Penally, Pembroke, Kilgetty, and Pembrokeshire, for a broad range of clients, including Homeowners, Holiday Lettings, Rental Accommodation, Commercial customers.

Insurance companies usually require that your property is inspected and tested regularly to ensure that it remains safe to use. If you would like your property inspected and tested, please get in touch for a no obligation quote.

Corroded pipe work leading to ineffective bonding to gas pipework

Corroded pipe work leading to ineffective bonding to gas pipework in Pembroke

why inspect and test?

Inspection and Testing is important to establish that an installation remains safe to use, and meets British Standards to remain compliant with legislation.

As you will see, the connection between the earth clamp and the gas pipe on this commercial installation has failed due to corrosion. This is an important connection since it ensures that unsafe voltages do not appear on the pipework.

Inspection and testing verifies that the electrical installation has not deteriorated into a dangerous condition, and ensures that the installation remains safe to use.

Poor connections can start a fire…

Poor connections can start a fire…

What happens during inspection and test?

The following tests/conditions are carried out / verified…

Verification of the continuity of protective conductors including main and supplementary equipotential bonding

Continuity of ring final circuit conductors

Insulation resistance (checks condition of the insulation around wires)

Protection by SELV, PELV or electrical separation

Basic protection by a barrier or enclosure provided during erection

Insulation resistance/impedance of floors and walls

Polarity

Earth electrode resistance

Protection by automatic disconnection of the supply

Earth fault loop impedance

Additional protection

Prospective fault current

Check of phase sequence

Functional testing

Verification of voltage drop

 
Burnt shower connection.jpg

Shower wiring

Connections can overheat due to corrosion/wear/loose connection

Loose connection on shower isolator.jpg

Loose connection on shower isolator

Showers consume a lot of power. If the connection becomes loose it will over heat and may start a fire.

Melted downlights in Tenby - due to installation with loft insulation